6Ka 1-Pole Overcurrent Circuit Breaker B 16A - E+1Mbn116E







Περιγραφή
Technical data: Number of poles protected: 1 Number of poles: 1 P Pole arrangement: 1 P Tripping characteristic: B Functions With switched N pole: no Electrical characteristics Rated short-circuit breaking capacity Icn: 6 kA Rated operational voltage Ue (AC):230 / 400 V Supply voltage type:AC Frequency:50/60 Hz Voltage Rated insulation voltage Ui:500 V Rated impulse withstand voltage Uimp:4000 V Current Rated current In:16 A Rated operating short-circuit breaking capacity Ics:6 kA Min./max. value of AC current at which time-delayed protection operates:1.13 / 1.45 In Min./max. value of AC current at which instantaneous protection operates:3 / 5 In Rated breaking capacity under 230V AC according to IEC 60898-1:6 kA Rated ultimate short-circuit breaking capacity Icu for ETIM (PN-EN 60947-2):6 kA Current / Temperature Rated current at temperature -25°C:22.2 A Rated current at temperature -20°C:21.69 A Rated current at temperature -15°C:21.19 A Rated current at temperature -10°C: 20.89 A Rated current at -5°C: 20.17 A Rated current at 0°C: 19.66 A Rated current at 5°C: 19.16 A Rated current at 10°C: 18.65 A Rated current at 15°C: 18.14 A Rated current at 20°C: 17.63 A Rated current at 25°C: 17.13 A Rated current at 30°C: 16 A Rated current at 35°C: 16.11 A Rated current at 40°C: 15.6 A Rated current at 45°C: 15.1 A Rated current at 50°C: 15 A Rated current at 55°C: 14.08 A Rated current at temperature of 60°C: 13.57 A Rated current at temperature of 65°C: 13.07 A Rated current at temperature of 70°C: 12.56 A Current correction factor Rated current correction factor for 2 devices installed side by side: 1 Rated current correction factor for 3 devices installed side by side: 0.95 Correction factor rated current for 4 or 5 devices installed side by side: 0.9 Rated current correction factor for 6 devices installed side by side: 0.85 Correction factor of the instantaneous release at a frequency of 100 Hz: 1.1 Correction factor of the instantaneous release at a frequency of 200 Hz: 1.2 Correction factor of the instantaneous release at a frequency of 400 Hz: 1.5 Correction factor of the instantaneous release at a frequency of 60 Hz: 1 Frequency Frequency (range to ETIM): 50 to 60 Hz Power Total power loss at rated current: 2.44 W Power loss per pole at rated current: 2.44 W Endurance Electrical durability (number of cycles): 4000 Mechanical durability (number of cycles): 20000 Dimensions Product depth: 70 mm Product height: 83 mm Product width:17.5 mm Installation / Mounting Tightening torque:2.8 Nm Product mounting position 360°:yes Connection Cross-section of flexible wire (stranded) in terminal:1 / 25mm2 Cross-section of rigid wire (solid) in terminal:1 / 35mm2 Input/output terminal capacity for rigid wire (solid):1 / 35 mm2 Input/output terminal capacity for flexible cable (stranded): 1 / 25 mm2 Type of connection: with screw Standard Standard: EN 60898-1 European WEEE directive: applicable Safety Degree of protection: IP20 Conditions of use Operating temperature: -25…70 °C Pollution degree according to IEC 60664 / IEC 60947-2.:2 Energy limitation class I2t.:3 Storage/transport temperature:-25…80 °C MCB Miniature circuit breaker Icn=6000A 1P B 16A ** Illustrative photo