Fluke 170 Series True-rms Digital Multimeters are the choice of professionals worldwide for their accuracy, reliability, and ease of use. They're the industry standard, with all the features you need to troubleshoot and repair countless electrical and electronic equipment problems.
Fluke 170 Series Digital Multimeters offer true-rms voltage and current measurement, 6000 count resolution, and manual and autoranging. They also offer frequency, capacitance, resistance, continuity, and diode measurements. Additionally, the Fluke 177 and 179 offer improved 0.09% basic accuracy and a backlit digital display with analog bargraph readout. The Fluke 179 also supports temperature measurement.
Fluke 170 Series Multimeters have been independently tested for safe use in: CAT IV 600 V/CAT III 1000 V Environment
□Features□
・Auto-ranging and manual ranging
・Display hold and auto-hold
・Frequency and capacitance measurements
・Resistance, continuity, and diode measurements
・Temperature measurements (179)
・Min, max, and average recording
・Front-panel calibration without opening the case
・Ergonomic case with integrated protective holster
□Specifications□
[DC Voltage] Accuracy: ±(0.09% + 2), Max Resolution: 0.1 mV, Max: 1000 V
[AC Voltage] Accuracy*: ±(1.0% + 3), Max Resolution: 0.1 mV, Max: 1000 V
[DC Current] Accuracy*: ±(1.0% + 3), Max Resolution: 0.01 mA, Max: 10 A
[AC Current] Accuracy*: ±(1.5% + 3), Max Resolution: 0.01 mA, Maximum: 10 A
[Resistance] Accuracy*: ±(0.9% + 1), Maximum Resolution: 0.1 Ω, Maximum: 50 MΩ
[Capacitance] Accuracy*: ±(1.2% + 2), Maximum Resolution: 1 nF, Maximum: 10,000 μF
[Frequency] Accuracy*: ±(0.1% + 1), Maximum Resolution: 0.01 Hz, Maximum: 100 kHz
[Temperature] Accuracy*: ±(1.0% + 10), Maximum Resolution: 0.1°C, Range: -40°C/+400°C
Note*: Accuracy is the maximum accuracy for each function.
Operating Temperature: -10°C to +50°C
Storage Temperature: -30°C to +60°C
Humidity (Non-Condensing): 0% to 90% (0°C to 35°C), 0% to 70% (35°C to 50°C)
Overvoltage Category: EN 61010-1 up to 1000V CAT III. EN 61010-1 up to 600V CAT IV
Certifications: UL, CSA, TUV certified, and VDE pending
Dimensions: 43 x 90 x 185 mm
Weight: 420g
True-rms voltage and current measurement, 6000 count resolution, manual and auto-ranging.
Frequency, capacitance, resistance, continuity, diode, and temperature measurements available. Plus, it features 0.09% basic accuracy and a backlit digital display with analog bar graph readout. Fluke 170 Series multimeters are independently tested for safe use in CAT IV 600 V/CAT III 1000 V environments.