Feature:
1. TWO MODES: The dual power automatic transfer switch can be operated automatically or manually. Can switch without power interruption in milliseconds, ensuring the continuity, reliability and safety of power supply. Has a compact structure, trusted transmit, convenient installation and maintenance, and a long service life
2. CONTINUOUS POWER SUPPLY: When there is an abnormality in the normal power supply, the backup power supply will immediately work to ensure the continuous power supply. When the normal power supply is turned on, ATS will automatically switch back from the backup power supply to the normal power supply
3. 35MM STANDARD RAIL: This automatic transfer switch is suitable for 50 or 60Hz AC rated 100A emergency power supply systems, which is specially designed for household rail mounting and is specifically used for PZ30 distribution boxes
4. STURDY MATERIAL: The uninterrupted dual power transfer switch is made of inflaming retarding PC material, which has good insulation, high temperature proof, and uses silver contacts to prevent aging. It is safe and trusted, greatly improving conductivity and service life
5. APPLICABLE SCENARIO: The dual power toggle controller adopts exquisite craftsmanship, with isolation and interference prevention, self switching and self resetting, and stable, which is used in various situations where continuous power outages are not allowed, such as homes, shopping malls, factories, laboratories, breeding farms, etc.
Specification:
Item Type: Dual Power Automatic Transfer Switch
Model: NLQ4 125 3P(III)
Material: PC inflaming retarding and silver
Specification: 3P
Rated Current(le): 100A
Frequency: 50 60HZ
Grade: PC level
Lifespan: Electrical: 2000 Times; Mechanical: 5000 Times
Rated Short Circuit Current: 50kA
Fusing: RT16 00 63A
Auxiliary Circuit: Two Relays, Each With Two Sets of Contacts Capacity: 50HZ le=5y
Touch Time: <50ms
Operating Conversion Time: <50ms
Return Time: <50ms
Closing Time: <50ms.
Package List:
1 x Dual Power Automatic Transfer Switch
4 x Connecting Wires
1 x User Manual
Note:
1. The highest ambient temperature should not exceed 40 celsius , the lowest should not be lower than 5 celsius , and the average temperature within 24 hours should not exceed 35 celsius .2. The installation location should not be at an altitude higher than 2000m.3. When the maximum temperature reaches 40 celsius , the relative humidity at the installation site should not exceed 50percent ; when the temperature is at the lowest 5 celsius , the relative humidity is higher, for example: at a temperature of 25 celsius , the relative humidity is 90percent .4. Due to temperature changes, special measures should be taken to deal with occasional condensation on the product appearance.